Polytherm 10 Zone 230V Wiring Centre
In stock
Product Code
U97238
The WB10 is an 10 Zone wiring centre for use with 230v thermostats the outline dimension is 32cm x 14cm x 5.5cm .the WB10 can be used to control any actuator or valve which requires a 230v AC signal to open. For mid position valves and those requiring a closing signal, a changeover relay is required.
At the same time the WB10 offers the ability to operate boiler or other heat source through a volt free output.
Additional outputs designed for use with under-floor heating systems are also included as standard. These are the pump and valve outputs which would normally operate a manifold pump or a manifold valve.
WB10 has a feature of pump delay , user could set it 3mins or 1min by adjusting the switch on the pcb , the pump output delay time is 3 minutes if switch is set to “1” ; the pump output delay time is 3 minutes if switch is set to “ON” ; the pump delay switch is close to the fuse on the pcb board.
TECHNICAL SPECIFICATIONS
1, Mains Supply: Power supply into the ten zone wire centre (WB10), which should be fused at 5 amps, 230v AC 50/60Hz
2, Heat Enable: This is the main call for heat for the system, there are 3 connections; LS = Live Supply E = Earth LR = Live Return
Electrically this is a volt free switch, whatever supply is placed on the LS connection, is fed to the LR connection when there is a call
for heat.
3, Zone 10: Zone 10 can be used as an isolated radiator zone, by using the UFH/RAD
4, 10 Zones input: the wiring center can connect to 10 thermostats
5, 10 zones output: the wiring center can connect to 10 valves
6, UFH Pump: Used for an underfloor heating manifold pump
7, UFH Valve: Used for an underfloor heating manifold valve.
8, Pump delay time: 3 minutes
At the same time the WB10 offers the ability to operate boiler or other heat source through a volt free output.
Additional outputs designed for use with under-floor heating systems are also included as standard. These are the pump and valve outputs which would normally operate a manifold pump or a manifold valve.
WB10 has a feature of pump delay , user could set it 3mins or 1min by adjusting the switch on the pcb , the pump output delay time is 3 minutes if switch is set to “1” ; the pump output delay time is 3 minutes if switch is set to “ON” ; the pump delay switch is close to the fuse on the pcb board.
TECHNICAL SPECIFICATIONS
1, Mains Supply: Power supply into the ten zone wire centre (WB10), which should be fused at 5 amps, 230v AC 50/60Hz
2, Heat Enable: This is the main call for heat for the system, there are 3 connections; LS = Live Supply E = Earth LR = Live Return
Electrically this is a volt free switch, whatever supply is placed on the LS connection, is fed to the LR connection when there is a call
for heat.
3, Zone 10: Zone 10 can be used as an isolated radiator zone, by using the UFH/RAD
4, 10 Zones input: the wiring center can connect to 10 thermostats
5, 10 zones output: the wiring center can connect to 10 valves
6, UFH Pump: Used for an underfloor heating manifold pump
7, UFH Valve: Used for an underfloor heating manifold valve.
8, Pump delay time: 3 minutes
Colour | White |
---|---|
Brand | Polytherm |
Manufacturer Part Code | PWB10 |
Power Supply | 230 V |
Product Type | Wiring Centre |
Depth | 55 mm |
Length | 140 mm |
Width | 320 mm |
Collection:
- You can select the branch where you would like to collect your order.
- We will send you an email when your order is ready to be collected.
- Orders received by 3pm can be collected in the branch during opening hours on the next working day if all stock is available in the local branch
- If we need to transfer some of your products from our central warehouse to your local branch, it may take 2-3 days for your order to be ready for collection
- You must report any damages, shortages or incorrect items to the showroom where you collected your order within 48 hours of collection.
Delivery:
- There is a delivery charge of €35 for any order under €500
- You will be contacted by the branch to confirm you delivery details. We will also send you an email to confirm when your order has gone out for delivery.
- Orders received by 3pm can be sent out for delivery during opening hours on the next working day if all stock is available in the local branch and a delivery slot is available. If our normal delivery service schedule is full, you will be contacted by the branch to agree alternative delivery details.
- You must report any damages, shortages or incorrect items to Customer Support within 48 hours of delivery.
Please note you can cancel your order at any time until receipt – see our Returns & Cancellations policy for further information.